G9SX
Flexible Safety Unit |
|
Logical AND connection enables partial or full control.
Uses solid-state output (excluding Expansion Units).
LED indicators provide details of failure diagnosis.
|
4
(EN954-1)
PLe
(ISO3849-1)
SIL3
(EN61508) |
EN50178
ISO13849-1
EN954-1
IEC/EN60204-1
IEC/EN61508
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
CAN/CSA C22.2
No.142 |
TÜV SÜD
UL
KOSHA
|
|
G9SX-GS
Safety Guard
Switching Unit |
|
Auto Switching and Manual Switching functions support two types
of application.
External indicator outputs enable indicating the switching
status of two safety input devices.
Auxiliary outputs enable monitoring of safety inputs, safety
outputs, and errors.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in
combination with other G9SX-series Units.
|
4
(EN954-1)
PLe
(ISO3849-1)
SIL3
(IEC/
EN61508,
IEC/
EN62061) |
EN50178
IEC/EN60204-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
IEC61508
CAN/CSA C22.2
No.142 |
TÜV Product Service
UL (cUL)
KOSHA
|
|
G9SX-SM
Standstill Monitoring Unit |
|
The back electromotive force (BEMF) signal is used to determine
when the motor has stopped.
A standard configuration for standstill detection enables
immediate application without setup.
User configuration to adjust settings for individual machines is
also possible.
Detailed indicator displays for fault diagnosis.
Certified for Safety Category 4 (EN 954-1), PLe (ISO 13849-1),
and SIL3 (IEC/EN 62061).
|
4
(EN954-1)
PLe
(ISO3849-1)
SIL3
(IEC/
EN62061) |
EN1088
EN50178
IEC/EN60204-1
ISO13849-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
CAN/CSA
C22.2 No.142 |
TÜV Product Service
UL (cUL)
|
|
G9SX-LM
Low-speed Monitoring
Unit |
|
Detects the motor speed with a proximity sensor.
Monitors to see if the motor is below the speed level that has
been set for the specific hazard source.
Enable switch input provided for maintenance work.
Detailed indicator displays for fault diagnosis.
Certified for Safety Category 3 (EN 954-1), PLd (ISO 13849-1),
and SIL3 (IEC/EN 62061).
|
4
(EN954-1)
PLe
(ISO3849-1)
SIL3
(IEC/
EN62061) |
EN1088
EN50178
IEC/EN60204-1
ISO13849-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
CAN/CSA
C22.2 No.142 |
TÜV Product Service
UL (cUL)
|
|
F3SX
Safety Controller |
|
Detects two wires shorted together with the self-diagnosis
function and specifies the location of the problem with the
communications function.
Tell I/O status at a glance from LED indicators.
Conforms to safety category 4 and SIL 3.
Controls up to four light curtain sets.
|
4
(EN954-1)
SIL3
(EN61508) |
EN61508
IEC61508
EN954-1
EN61000-6-2
EN61000-6-4
EN61496-1
IEC61496-1
EN60204-1
IEC60204-1
EN50178
EN55011
UL508
UL1998 |
TÜV SÜD
UL (cUL)
KOSHA *2
|
|
G9SA
Safety Relay Unit |
|
Compact design.
Two-hand Controller model available.
Simple connection of Expansion Unit.
High-speed 10-ms response.
Incorporates LED indicators for monitoring built-in relays.
Finger protection construction.
3-pole, 5-pole and Off-delay Units available.
|
4
(EN954-1)
PLe
(ISO13849-1)
3
(OFF-delay contact) |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 GB14048.5 |
BG
UL
CSA
CQC
|
|
G9SB
Safety Relay Unit |
|
Ultra-compact, with models starting at only 17.5 mm wide.
Can be used with Safety Sensors.
High-speed 10-ms response.
Incorporates LED indicators for monitoring built-in relays.
Finger protection construction.
|
4
(EN954-1)
PLe
(ISO13849-1)
3/PLd * |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 GB14048.5 |
TÜV Rheinland
UL
CSA
CQC
|
|
G9S
Safety Relay Unit |
|
Two-pole, three-pole, five-pole, and OFF-delay models are
available.
Incorporates LED indicators for monitoring built-in relays.
Finger-protection construction.
|
4
(EN954-1)
3
(OFF-delay contact) |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 GB14048.5 |
BIA
UL
CSA
CQC
|
|
G9SA-300-SC
Safety Relay Unit
(Sensor Connector Type) |
|
Sensor connectors allow direct connection to F3SN-A, F3SN-B and
F3SH-A.
Reduces wiring and prevents incorrect connection.
Connection to emergency stop switch also supported.
|
4 (connect with F3SN-A/ F3SH-A)
2 (connect with F3SN-B) |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 |
TÜV Rheinland
UL
CSA
|
|
CQM1-SF200/ CS1W-SF200
Safety Relay Unit |
|
PLC I/O Unit-type safety relay.
Can be used with OMRON PLC models CQM1H and CS1.
The monitor signal of the safety circuit connects directly to
the CPU of the PLC through the internal bus.
Simplified wiring and space-saving construction.
|
4 |
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 |
TÜV Rheinland
UL
CSA
|
|
F3SP-B1P
Control Unit for
Safety Sensor |
|
Control Unit for F3SN-A, F3SN-B, and F3SH-A.
Plug in light curtain connectors on both sides.
|
4
(F3SN-A,
F3SH-A)
2
(F3SN-B)
** |
DEMKO and UL certified in a set with F3SN-A, F3SN-B, and F3SH-A.
|
|
F3SP-U2P
Safety Sensor Muting
Controller |
|
Adds muting function to Safety Sensors.
Connects to a maximum of 2 Safety Sensors.
|
4 (connected to Type 4 Sensors)
2
(connected to Type 2 Sensors) |
IEC61496-1 |
TÜV SÜD
UL (cUL)
|