Industrial Automation|

New Zealand

Clearance Centre

Sitemap

Contact

OMRON IA Global

 
Selection Guide
 

Main :: Safety Solutions :: Safety Application Controllers

 

 

Model

Appearance

Features

Safety Category

Approved Standard No.

Agency

G9SX

Flexible Safety Unit

G9SX Flexible Safety Unit

• Logical AND connection enables partial or full control.

• Uses solid-state output (excluding Expansion Units).

• LED indicators provide details of failure diagnosis.

4

(EN954-1)

 

PLe
(ISO3849-1)

 

SIL3

(EN61508)

EN50178

ISO13849-1
EN954-1
IEC/EN60204-1
IEC/EN61508
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
CAN/CSA C22.2
No.142

• TÜV SÜD

• UL

• KOSHA

G9SX-GS

Safety Guard Switching Unit

G9SX-GS Safety Guard Switching Unit

• Auto Switching and Manual Switching functions support two types of application.

• External indicator outputs enable indicating the switching status of two safety input devices.

• Auxiliary outputs enable monitoring of safety inputs, safety outputs, and errors.

• Detailed LED indications enable easy diagnosis.

• Logical AND connection allows complicated applications in combination with other G9SX-series Units.

4
(EN954-1)

 

PLe
(ISO3849-1)


SIL3
(IEC/
EN61508,
IEC/
EN62061)

EN50178
IEC/EN60204-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
IEC61508
CAN/CSA C22.2
No.142

• TÜV Product Service

• UL (cUL)

• KOSHA

G9SX-SM

Standstill Monitoring Unit

G9SX-SM Standstill Monitoring Unit

• The back electromotive force (BEMF) signal is used to determine when the motor has stopped.

• A standard configuration for standstill detection enables immediate application without setup.

• User configuration to adjust settings for individual machines is also possible.

• Detailed indicator displays for fault diagnosis.

• Certified for Safety Category 4 (EN 954-1), PLe (ISO 13849-1), and SIL3 (IEC/EN 62061).

4
(EN954-1)

 

PLe
(ISO3849-1)


SIL3
(IEC/
EN62061)

EN1088
EN50178
IEC/EN60204-1
ISO13849-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
CAN/CSA
C22.2 No.142

• TÜV Product Service

• UL (cUL)

G9SX-LM

Low-speed Monitoring Unit

G9SX-LM Low-speed Monitoring Unit

• Detects the motor speed with a proximity sensor.

• Monitors to see if the motor is below the speed level that has been set for the specific hazard source.

• Enable switch input provided for maintenance work.

• Detailed indicator displays for fault diagnosis.

• Certified for Safety Category 3 (EN 954-1), PLd (ISO 13849-1), and SIL3 (IEC/EN 62061).

4
(EN954-1)

 

PLe
(ISO3849-1)


SIL3
(IEC/
EN62061)

EN1088
EN50178
IEC/EN60204-1
ISO13849-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
CAN/CSA
C22.2 No.142

• TÜV Product Service

• UL (cUL)

F3SX

Safety Controller

F3SX Safety Controller

• Detects two wires shorted together with the self-diagnosis function and specifies the location of the problem with the communications function.

• Tell I/O status at a glance from LED indicators.

• Conforms to safety category 4 and SIL 3.

• Controls up to four light curtain sets.

4

(EN954-1)

 

SIL3

(EN61508)

EN61508
IEC61508
EN954-1
EN61000-6-2
EN61000-6-4
EN61496-1
IEC61496-1
EN60204-1
IEC60204-1
EN50178
EN55011
UL508
UL1998

• TÜV SÜD

• UL (cUL)

• KOSHA *2

G9SA

Safety Relay Unit

G9SA Safety Relay Unit

• Compact design.

• Two-hand Controller model available.

• Simple connection of Expansion Unit.

• High-speed 10-ms response.

• Incorporates LED indicators for monitoring built-in relays.

• Finger protection construction.

• 3-pole, 5-pole and Off-delay Units available.

4

(EN954-1)

 

PLe
(ISO13849-1)

 

3

(OFF-delay contact)

EN60204-1
EN954-1
UL508
CSA C22.2
No.14

GB14048.5

• BG

• UL

• CSA

• CQC

G9SB

Safety Relay Unit

G9SB Safety Relay Unit

• Ultra-compact, with models starting at only 17.5 mm wide.

• Can be used with Safety Sensors.

• High-speed 10-ms response.

• Incorporates LED indicators for monitoring built-in relays.

• Finger protection construction.

4

(EN954-1)

 

PLe
(ISO13849-1)

 

3/PLd *

EN60204-1
EN954-1
UL508
CSA C22.2
No.14

GB14048.5

• TÜV Rheinland

• UL

• CSA

• CQC

G9S

Safety Relay Unit

G9S Safety Relay Unit

• Two-pole, three-pole, five-pole, and OFF-delay models are available.

• Incorporates LED indicators for monitoring built-in relays.

• Finger-protection construction.
 

4

(EN954-1)

 

3

(OFF-delay contact)

EN60204-1
EN954-1
UL508
CSA C22.2
No.14

GB14048.5

• BIA

• UL

• CSA

• CQC

G9SA-300-SC

Safety Relay Unit (Sensor Connector Type)

G9SA-300-SC Safety Relay Unit (Sensor Connector Type)

• Sensor connectors allow direct connection to F3SN-A, F3SN-B and F3SH-A.

• Reduces wiring and prevents incorrect connection.

• Connection to emergency stop switch also supported.

4 (connect with F3SN-A/ F3SH-A)

2 (connect with F3SN-B)

EN60204-1
EN954-1
UL508
CSA C22.2
No.14

• TÜV Rheinland

• UL

• CSA

CQM1-SF200/ CS1W-SF200

Safety Relay Unit

CQM1-SF200 / CS1W-SF200 Safety Relay Unit

• PLC I/O Unit-type safety relay.

• Can be used with OMRON PLC models CQM1H and CS1.

• The monitor signal of the safety circuit connects directly to the CPU of the PLC through the internal bus.

• Simplified wiring and space-saving construction.

4

EN60204-1
EN954-1
UL508
CSA C22.2
No.14

• TÜV Rheinland

• UL

• CSA

F3SP-B1P

Control Unit for Safety Sensor

F3SP-B1P Control Unit for Safety Sensor

• Control Unit for F3SN-A, F3SN-B, and F3SH-A.

• Plug in light curtain connectors on both sides.

4
(F3SN-A,
F3SH-A)


2
(F3SN-B)

**

DEMKO and UL certified in a set with F3SN-A, F3SN-B, and F3SH-A.

F3SP-U2P

Safety Sensor Muting Controller

F3SP-U2P Safety Sensor Muting Controller

• Adds muting function to Safety Sensors.

• Connects to a maximum of 2 Safety Sensors.

4 (connected to Type 4 Sensors)

2

(connected to Type 2 Sensors)

IEC61496-1

• TÜV SÜD

• UL (cUL)

 

Note:

1: Production of the G9D-EX411 (Expansion Unit) and G9D-301 24V AC/DC Model have been discontinued at the end of March 2006. The recommended substitute will be the G9S-501 24V AC/DC, G9SA-501 24V AC/DC, G9S-301 24V AC/DC and G9SA-301 24V AC/DC Models.

2: The F3SX-[]-S is S-mark certified.

 

*   The G9SB-3010 can be applied to Safety Category 3 of the EN954-1 if double breaking is used for the G9SB-3010 Power Supply.

** The safety category refers to the highest applicable category that can be selected when a safety block is created for a control system. It is not the safety category applicable to the safety component itself.

 

top

 

Back