Model

Appearance

Features

Safety Category

Approved Standard No.

Agency

OS3101

Safety Laser Scanner

 

OS3101 Safety Laser Scanner

 

• Operator presence detection in work areas with complex shapes.

• Can be set a protective area with a 4-m radius and a warning area with a 15-m radius.

• When the OS3101 detects an object entering the protective area, the intrusion indicators immediately light in red. The positions of the lit indicators from among the total of 16 indicators show the direction of the intrusion.

• Two patterns of protective and warning area combinations can be set to enable responding to complex changes in the work area.

• Complex area settings can be made using the setting software.

3

EN61496-1/-3
UL508/UL1998

• TÜV Rheinland

• UL (cUL)

UM/UMM

Safety Mat System

 

UM/UMM Safety Mat System

 

• Safety Category 3 (EN 954-1) in combination with a special Controller. Connectors for easy connection to multiple Mats.

• Wide range of Mat sizes available.

• EN 1760-1 and EN 954-1 (Category 3) certification received.

• Compliance with North American safety standards, including ANSI/RIA 15.06-1999.

3

EN1760-1

EN954-1

• TÜV Rheinland

• CSA

SGE/SCC

Safety Edge/

Edge Controller

 

SGE/SCC Safety Edge/Edge Controller

 

• Combine the Safety Edge with a special Edge Controller to achieve safety category 3 (when directly shutting OFF source of hazard with built-in relay).

• Simple structure combining the sensor section and cover.

• Operates for pressure from the side and available with sensor lengths of 150 to 6,100 mm and sensor heights of 34 to 80 mm to support a wide range of applications.

• Certified for EN 1760-2 (safety edge standard).

3

EN1760-2

• TÜV NORD

 

Note: The safety category refers to the highest applicable category that can be selected when a safety block is created for a control system. It is not the safety category applicable to the safety component itself.