Product
Index :: Safety Solutions ::
Safety Controllers
|
DeviceNet Safety System
|
|
|

|
* Ordering information
* Specifications
* Configurations
* Dimensions, and etc
|
|
can be found in our PDF brochure.
|
|
Safety Controllers with
Reduced Network Wiring that Complies with Industry's Highest Safety
Standards
Achieve safety control through programming
and network.
Reduced wiring with safety networks. Connect
up to 32 Safety Terminals.
EN954-1 (Cat.4), ISO13849-1 (PLe), and IEC
61508 SIL3 certification.
A full lineup provides optimal solutions for
a variety of customer needs.
>>
Inquiry |
|
|
Product
Lineup
|
|
Safety Controller
Selection Guide

Top
Safety Network Controller - NE0A-SCPU01
|
|

Datasheet |
Lineup for Safety
Applications with Up to 12 Inputs
Circuits for the required safety
category are easy to build.
The safety circuits you create can be
registered as templates and reused, for easy standardization.
A wide range of TάV-certified
templates is also available.
The NE0A operating conditions can be
monitored from a standard DeviceNet Master.
Network distribution is possible by
combining with an NE1A Safety Controller.
|
Safety Network Controller - NE1A-SCPU01-V1/NE1A-SCPU02
|
|

Datasheet |
Programmable Safety
Control
Compact Safety Controller.
The NE1A-SCPU01-V1 provides 16
built-in safety
inputs and 8 built-in safety outputs.
The NE1A-SCPU02 provides 40 built-in safety inputs and 8 built-in
safety outputs.
Reduced wiring with safety networks.
Connect up to 32 Safety Terminals.
Monitor the safety system from
Standard Controllers across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe), and
IEC 61508 SIL3 certification.
|
Safety Network Controller - NE1A-SCPU0[]-EIP
|
|
![NE1A-SCPU0[]-EIP Ethernet/IP Safety Network Controller](NE1A-EIP.jpg)
Datasheet
|
Directly Connected to
SYSMAC CS/CJ Series via EtherNet/IP
Monitors safety systems via
EtherNet/IP.
Equipped with master functions of
DeviceNet Safety.
Does not require external devices for
connecting
Safety Network Controller and EtherNet/IP.
Increased maintainability in
combination with
OMRONs EtherNet/IP compatible PLC.
EN954-1 (Cat.4), ISO13849-1 (PLe), and
IEC 61508 SIL3 certification.
|
|
 |
Safety I/O Terminals - DST1 Series
|
|

Datasheet |
Distributed Safety
Terminals That Reduce Wiring
Lineup includes four
models to accommodate various I/O types and number of I/O points.
Monitor the safety
system from Standard Controllers across the network.
EN954-1 (Cat.4),
ISO13849-1 (PLe), and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1
also supports logic operation functions for high-speed processing in
applications requiring partial stopping of the safety system.
|
Safety Network Configurator
- WS02-CFSC1-E
|

Datasheet |
Programming Software
for Creating Safety Circuits
Performs settings for
the Safety Network Controllers and Safety I/O Terminals.
Provides safety
circuit programming functions.
Provides monitoring
functions for safety circuits.
Includes DeviceNet
Configurator functions.
|
Mobile
Console - NE1A-HDY01
|

Datasheet |
Mobile Type Maintenance
Terminal Dedicated for DeviceNet Safety Network
Enables easy monitoring and
replacement of devices by just connecting to NE0A/NE1A Safety
Controller with a USB cable.
Reliable safety operation without
requiring PC on site.
Contributes to shorten maintenance time
such as identifying error locations.
Easy-to-see screen display supports the
secure operation.
Lightweight and compact body with touch
screen also reduces work load.
The equipped memory card slot enables
easy programming and setting changes on site.
|
Ethernet/IP-DeviceNet Router -NE1A-EDR01
|
|

Datasheet |
Allows a Safety System
to be Monitored from Ethernet
The safety system can be remotely
operated with a personal computer.
The safety system can also be
monitored by an Ethernet-compatible PLC of another brand.
UDP packet messages supported.
|
|
|
Top |
Benefits / Features
|
|
TCO Reduction with an
OMRON Safety Controller

Raising Design
Efficiency with Programmable Safety Circuit Design

-
Work involving complicated safety
design is dramatically improved.
-
Safety circuits can be improved and
flexibly changed.
-
Safety logic is easily understandable
by machine designers.
Safety Design Solutions

|
Problems/Situations |
Solutions
of DeviceNet Safety System |
|
Vast amount of wiring for
connections between circuits and devices.
Complicated safety circuit, making
changes or expansion at production line become difficult. |
Compatible with the DeviceNet open
network, reduce wiring and easy expansion of Safety I/O through network.
Programmable and easy-to-design safety circuit
made changes simple and flexible (high expandability).
Safety circuit monitoring by PLC. |
DeviceNet Safety System provides
monitoring of distributed safety devices and enables easy changes on production
line. The adjustment to shorten product life cycles become easy, thus improving maintenance efficiency.
|
|
Top |
See Related Products:

|
Safety Light Curtain
F3SJ
Simple. Easy to use. The new standard
in Safety Light Curtains. |

|
Safety Relay Unit
G9S
Ideal for safety door and emergency
stop switch circuits. |

|
Flexible Safety Unit
G9SX
Logical AND function adds flexibility
to I/O expansion. |

|
Safety Laser Scanner
OS3101
Operator presence detection in work
areas with complex shapes. |
|
|
 |
|