Easy Ladder Programming with
Smart Input
[Ladder Programming: 30%
Faster]
Note: In the case of program capacity 1.5
Ksteps
Easy Input Editor
Instruction and Address
Input Assist Functions
When you begin typing an instruction from the keyboard in Ladder Editor
Mode, suggested instructions are displayed and the addresses are
automatically entered.
Connecting lines are added automatically based on the cursor position,
enabling intuitive ladder programming.

User-friendly Ladder Program
Input
Automatic Connecting Line
Insertion
With the automatic connecting line insertion function the necessary
connection is added automatically based on the curser position.

Automatic Column Insertion
When Inserting Instructions
The column is automatically inserted when an instruction is added even if
the curser is above another instruction.

Easily Reuse Ladder
Programming
Copying with Address
Incrementing
To create the same group of ladder instructions more than once, with the
address addition copy function, the instructions can be reused simply by
inputting an address offset.

Intuitive Menu Structure
Intuitive Menu Display
An intuitively designed menu structure makes it easy to see the overall
system simply by looking at the menu for smooth operation without referring
to a manual.

top
Commercially Available USB
Cables Can Be Connected
CP1E CPU Units use USB for the peripheral port. Computers can be connected
using commercially available USB cables. Without the need for USB conversion
cables or special cables, connection is easier and cable cost is low.

top
I/O Status at a Glance
The terminal layout display features I/O indicators. The indicators are in
the same position as the terminals to let you see the I/O status at a
glance. You can easily identify I/O status or perform status checks at
startup or during operation.

top
More Applications with Advanced
Control Capabilities and Functionality (N-/NA-type only)
The CP1E N/NA-type CPU Units are equipped with high-speed counters, pulse
outputs, and a built-in serial port. An option board for an additional
Serial or Ethernet communication port is available. These features enable controlling a
wide range of devices.

top
Analog Control and
Monitoring with Only a Single CPU Unit.

top
Ethernet Communications
NEW!
Mount a CP1W-CIF41 Ethernet Option Board
to an option board slot on the CP1E-N/NA type CPU Unit. Perform
monitoring and programming with CX-Programmer, or communicate with a
host computer via Ethernet.

top
Pulse Outputs
Two 100kHz pulse outputs for high-precision position control.

top
Note: Models with transistor outputs.
Modbus-RTU Easy Master
Specify Inverter speeds via RS-485.

top
High-speed Counters
Control multiple axes with one PLC using the two 100kHz and four 10kHz,
single-phase high-speed counters.

top
Serial PLC Links
Link data with up to 10 words between up to nine CP1E-N CPU Units when
controlling a device with multiple CP1E-N Micro PLCs.

top
Optional Units for More
Flexibility
Three expansion units are available. An option board for an additional
Serial or Ethernet communication port can be added to N/NA-type CPU unit.

|