Semi S2-0200
12.4 All emergency off buttons should be
clearly labeled as "EMO," "Emergency Off," or the equivalent and should be
clearly legible from the viewing location. The label may appear on the button or
on the yellow background.

SEMATECH Application Guide for
SEMI S2-93
12.4.c The EMO
should be located in an area not subject to accidental activation. If a
button guard is installed, its diameter should be no less than 75 mm (3
inches) with the button recessed no more than 3 mm (0.125 inches) from the
front of the guard, or equivalently configured to allow for palm
activation.
Note: The EMERGENCY OFF
legend plate is not provided in a set. Prepare separately or purchase the
A22Z-3466-2.
|
Details |
Model |
|
Spacer not
included |
A22Z-EG2 |
|
Spacer
included (one) |
A22Z-EG21 |
|
Spacers
included (two) |
A22Z-EG22 |
|
EMERGENCY
OFF legend plate |
A22Z-3466-2 |
Note:
This product can be used when configuring a
safety system complying with SEMI S2-0200 and SEMATECH Application Guide
for SEMI S2-93.
This product conforms to these standards provided that it is used in
combination with an OMRON A22E-series Emergency Stop Switch. |